BULLETIN
NO. 1400
AIR CLEANING SYSTEMS AND
EQUPMENT BY
R. M.E. I., INC. |
|
|
The Competitive Edge - Filter-Mate Has it all. Here's Why...
|
- Eliminates
"in the room" air cleaners which are unsightly, expensive,
noisy, and take up valuable space. Our units work above the ceiling
in either the existing CH&A ductwork systems, or an easily installed
independent flex duct system.
- Modular
filter housings and motor-blower housings are separate. They
can easily be connected to form one unit or placed in separate locations
connected by a duct line.
- Modular
motor-blower housing assemblies offset the additional pressure drop
created by the filter bank and maintains the original balanced flow
of the HVAC system.
- Side
loaded filter housings accept up to five stages of progressive
density filtration for efficient filter application. Filter choices
include: panel prefilters, mist collectors, spark arrestors, extended
surface pleats, V-bags, HEPAS, partial bypass or solid bed panels containing
up to 90 pounds of activated charcoal or activated alumina. Multiple
height-width filter housings are available.
- The
ability for you to select a "filter-motor-blower" combination
provides for unlimited versatility.
- Motor-blower
housings accept motors of any frame and size and blowers from
100 to 50,000 cfm.
- Our
Technical and engineering support helps you select the
correct filter-motor-blower combinations for your particular application.
|
|
Filter-Mate...
Built to Last |
- Modular
- Compact
- U.L.
Listed Electrical Componets
- Rugged
Construction
- Fully
Sealed
- Easy
Installation
- Quiet
Operation
- Easy
To Service
- Non
Electrostatic
- Energy
Efficient
- Side
Access
- Removes
Particulates
- Remove
Odors
|
|
|
APPLICATIONS |
RESIDENTIAL:
|
Remove Dust, pollen, mold spores, cooking odors, cigarette smoke,
formaldehyde. |
COMMERCIAL:
|
Remove heavy cigarette smoke and odors, food odors, restroom odors,
paper dust, toner dust. |
INDUSTRIAL:
|
Remove welding fumes, airborn dusts, airborn lint and fibers, odors,
vapors, gasses, oil mists, smoke, cotton dusts, asbestos |
|
HOW TO SPECIFY DESIGN & CONSTRUCTION |
The MH-series shall be a side access air handling system consisting of a
housing with positively sealed, hinged access door(s), Motor and belt drive
at blower. Cabinet is made of 16 gage galvanized steel with 1-1/2 standing
flanges and 2 channel corner posts designed to interface with FH-series
filter housings and ductwork. Electrical wiring is terminated at an externally
mounted junction box. Drive section consists of adjustable pitch sheave,
solid cast iron sheave and heavy duty V-belt. Motor mount is adjustable
for controlling belt tension. motor, blower size, and electrical requirements
vary according to model.
The FH-series shall be a side access with multi-stage filter system consisting
of a housing, access door(s), tracks and universal holding frames. Housing
shall accept filter combinations listed under specifications. The cabinet
consists of 16 gage galvanized steel with 1-1/2 standing flanges and 2 channel
corner posts designed to interface with MH-series Motor-blower housings
and ductwork. Access doors are 16 gage galvanized steel with replaceable
positive sealing latches and replaceable hinges. Access doors and filter
compartment is gasketed for air tight seal. Flanges are notched for water
runoff and cabinets are suitable for out door installation.
|
APPLICATION
|
The MH-series air handlers are used to push or draw air through FH-series
filter housings. The aire handler system and filter housing can be used
separately or together with or without ductwork to provide a high efficiency
air cleaning system capable of accepting a wide variety of high efficiency
media filtration. Filter media types would include prefilters, pleated cartriges,
V-bags, HEPAS, activated charcoal and activated alumina, mist collectors
and spark arrestors. In a commercial application this system is designed
to operate as an independently concealed system above the ceiling. It can
either operate separate and indepent of the central heat and air system
or in conjunction with an existing system. In an industrial application
this system can also be used in a free hanging position for general air
cirulation. It can be attached to one or more pick up hoses for direct source
capture or aattached to a canopy hood for general source in welding, grinding,
cutting and boring operations. |
FILTER-MATE®
Filter Housing Assembly Specifications |
Model |
DIMENSION
H x W x D
(inches) |
SHPG.
WT.
(lbs) |
C.F.M
at
500 F.P.M.
face
velocity |
SER-
VICE
CLR.
(in) |
FILTER
Stages*
(max.) |
Quantity
&
Filter Face
Dimension**
(inches) |
Filter
Combinations
Availble |
FH-14
- 1/2 x 1
FH-14 - 1 x 1
FH-14 - 1 x 2
FH-14 - 1 x 3
FH-14 - 2 x 2
FH-14 - 2 x 3
FH-14 - 3 x 3 |
27.25
x 24 x 14
27.25 x 48 x 14
27.25 x 72 x 14
51.50 x 48 x 14
51.50 x 72 x 14
75.75 x 72 x 14 |
43
65
80
100
131
175 |
1000
2000
3000
4000
6000
9000 |
26"
26"
26"
26"
26"
26" |
two
two
two
two
two
two |
1
- 24 x 24
2 - 24 x 24
3 - 24 x 24
4 - 24 x 24
6 - 24 x 24
9 - 24 x 24 |
ASHRAE
or
charcoal |
FH-21
- 1/2 x 1
FH-21 - 1 x 1
FH-21 - 1 x 2
FH-21 - 1 x 3
FH-21 - 2 x 2
FH-21 - 2 x 3
FH-21 - 3 x 3 |
15.25
x 24 x 21
27.25 x 24 x 21
27.25 x 48 x 21
27.25 x 72 x 21
51.50 x 48 x 21
51.50 x 72 x 21
75.75 x 72 x 21 |
92
120
173
232
254
332
430 |
1000
2000
4000
6000
8000
12000
18000 |
26"
26"
26"
26"
26"
26"
26" |
two
two
two
two
two
two
two |
1
- 12 x 24
1 - 24 x 24
2 - 24 x 24
3 - 24 x 24
4 - 24 x 24
6 - 24 x 24
9 - 24 x 24 |
2"
prefilter + 12" pleated
ASHRAE or charcoal |
FH-27
- 1 x 1
FH-27 - 1 x 2
FH-27 - 1 x 3
FH-27 - 2 x 2
FH-27 - 2 x 3
FH-27 - 3 x 3 |
28.5
x 26.38 x 27
28.5 x 52.00 x 27
28.5 x 76.50 x 27
52.5 x 52.00 x 27
52.5 x 77.63 x 27
76.5 x 77.63 x 27 |
170
242
311
340
418
519 |
2000
4000
6000
8000
12000
18000 |
26"
26"
26"
26"
26"
26" |
two
two
two
two
two
two |
1
- 24 x 24
2 - 24 x 24
3 - 24 x 24
4 - 24 x 24
6 - 24 x 24
9 - 24 x 24 |
99.97
D.O.P. standard
or high capacity |
FH-33
- 1/2 x 1
FH-33 - 1 x 1
FH-33 - 1 x 2
FH-33 - 1 x 3
FH-33 - 2 x 2
FH-33 - 2 x 3
FH-33 - 3 x 3 |
15.25
x 24 x 33.75
27.25 x 24 x 33.75
27.25 x 48 x 33.75
27.25 x 72 x 33.75
51.50 x 48 x 33.75
51.50 x 72 x 33.75
75.75 x 72 x 33.75 |
120
155
224
300
328
429
556 |
1000
2000
4000
6000
8000
12000
18000 |
33"
33"
33"
33"
33"
33"
33" |
three
three
three
three
three
three
three |
1
- 12 x 24
1 - 24 x 24
2 - 24 x 24
3 - 24 x 24
4 - 24 x 24
6 - 24 x 24
9 - 24 x 24 |
2"
or 4" prefilter + 12"
pleated ASHRAE
+ 8" solid bed charcoal OR
4" oil coelescer
or spark arrestor +
2" prefilter +
12" pleated ASHRAE OR
4" oil coelescer
or spark arrestor +
2" prefilter + 24" V-bag |
FH-42
- 1 x 1
FH-42 - 1 x 2
FH-42 - 1 x 3
FH-42 - 2 x 2
FH-42 - 2 x 3
FH-42 - 3 x 3 |
27.25
x 24 x 42
27.25 x 48 x 42
27.25 x 72 x 42
51.50 x 48 x 42
51.50 x 72 x 42
75.75 x 72 x 42 |
235
340
456
500
653
845 |
2000
4000
6000
8000
12000
18000 |
36"
36"
36"
36"
36"
36" |
four
four
four
four
four
four |
1
- 24 x 24
2 - 24 x 24
3 - 24 x 24
4 - 24 x 24
6 - 24 x 24
9 - 24 x 24 |
OR
2" prefilter + 36" V-bag |
FH-33-CF
- 1/2 x 1
FH-33-CF - 1 x 1
FH-33-CF - 1 x 2
FH-33-CF - 1 x 3
FH-33-CF - 2 x 2
FH-33-CF - 2 x 3
FH-33-CF - 3 x 3 |
15.25
x 24 x 33.75
27.25 x 24 x 33.75
27.25 x 48 x 33.75
27.25 x 72 x 33.75
51.50 x 48 x 33.75
51.50 x 72 x 33.75
75.75 x 72 x 33.75 |
200
330
527
800
920
1202
1550 |
1000
2000
4000
6000
8000
12000
18000 |
33"
33"
33"
33"
33"
33"
33" |
two
two
two
two
two
two
two |
1
- 12 x 24
1 - 24 x 24
2 - 24 x 24
3 - 24 x 24
4 - 24 x 24
6 - 24 x 24
9 - 24 x 24 |
2"
prefilter + 90 lbs.
of virgin activated
charcoal in 10 refillable
trays per 24" x 24"
face area
--
Activated
Alumina
Optional -- |
**
Accepts holding frame or headered primary
HOW TO ORDER: State model, housing size, filter size,
type, efficiency, and quantity.
Design and Specifications subject to change without notice. |
|
SUGGESTED HOUSING ARRANGEMENTS |
APPLICATION |
AIRFLOW
|
HOSPITAL |
Prefilter
95% ASHRAE
Motor/Blower
99% HEPA |
COMMERCIAL |
Prefilter
95% ASHRAE or 95% HEPA
Motor/Blower
Charcoal
40% ASHRAE |
INDUSTRIAL |
Prefilter
55-95% ASHRAE
95% HEPA
Charcoal
Motor/Blower
|
OIL
MIST |
Mist Collector
Prefilter
95% ASHRAE
Motor/Blower
|
* Certain Stages may be deleted or added depending on the specific
application.
# Diffuser location if Motor housing interfaces directly with downstream
filter. |
|
FILTER-MATE®
Motor-blower Assembly Specifications
Commercial Models |
MODEL |
DIMENSION
H x W x D
(inches) |
SHPG.
WT.
(lbs) |
SER-
VICE
CLR.
(in) |
MOTOR |
BLOWER
WHEEL
Diam. x Width (in)
forward inclined |
C.F.M. at external
static pressure.
R.P.M.* |
MH-21 - 1/2 x 1 |
15.50 x 24 x 21 |
|
|
1/3 H.P., 115 V.A.C., F.L.A. 6.0, 1725 rpm 60 Hz. |
7 x 5 |
600 cfm @ 1.3" TSP, 1800 rpm, BHP .27 |
MH-23
- 1/2 x 1 |
15.50
x 24 x 23 |
93 |
49 |
1/3
H.P., 115 V.A.C., F.L.A. 6.0, 1725 rpm 60 Hz. |
9
x 7 |
800
cfm @ 0.70" TSP, 850 rpm, BHP .16 |
MH-33 - 1/2 x 1 |
15.50 x 24 x 23 |
|
|
1/2 H.P., 115 V.A.C., F.L.A. 8.0, 1725 rpm 60 Hz. |
9 x 7 |
1000 cfm @ 1.5" TSP, 1257 rpm, BHP .43 |
MH-23
- 1 x 1 |
27.25
x 24 x 23 |
127 |
55 |
3/4
H.P., 115/230 V.A.C., F.L.A. 11.4/5.7, 1725 rpm 60 Hz. |
10
x 10 |
2000
cfm @ 1.0" TSP, 950 rpm, BHP .70 |
MH-33 - 1 x 1 |
27.25 x 24 x 33.75 |
|
|
2.0 H.P., 230/460 V.A.C., F.L.A. 6.0/3.0, 1725 rpm 60 Hz. 3 Phase |
12 x 12 |
2500 cfm @ 1.8" TSP, 1106 rpm, BHP 1.23 |
MH-42
- 1 x 2 |
27.25
x 48 x 42 |
300 |
67 |
3.0
H.P., 230/460 V.A.C., F.L.A. 8.4/4.2, 1725 rpm 60 Hz. 3 Phase |
15
x 15 |
5000
cfm @ 1.80" TSP, 912 rpm, BHP 2.90 |
MH-42 - 1 x 3 |
27.25 x 48 x 42 |
|
|
5.0 H.P., 230/460 V.A.C., F.L.A. 13.0/6.5, 1725 rpm 60 Hz. 3 Phase |
15 x 15 |
6000 cfm @ 1.80" TSP, 933 rpm, BHP 4.05 |
MH-50
- 2 x 2 |
51.50
x 48 x 50 |
450 |
55 |
5.0
H.P., 230/460 V.A.C., F.L.A. 13.0/6.5, 1725 rpm 60 Hz. 3 Phase |
18
x 18 |
8000
cfm @ 1.80" TSP, 750 rpm, BHP 4.35 |
MH-57 - 2 x 3 |
51.50 x 72 x 57 |
|
|
10 H.P., 230/460 V.A.C., F.L.A. 24.6/12.3, 1725 rpm 60 Hz. 3 Phase |
20 x 20 |
12000 cfm @ 2.0" TSP, 755 rpm, BHP 7.90 |
MH-57
- 3 x 3 |
75.75
x 72 x 57 |
750 |
68 |
15
H.P., 230/460 V.A.C., F.L.A. 38.0/19.0, 1725 rpm 60 Hz. 3 Phase |
22
x 22 |
18000
cfm @ 2.0" TSP, 754 rpm, BHP 14.30 |
*Larger Models availible up to 50,000 cfm on a custom order basis.
Backward inclined and airfoil fans availble for higher static pressure
requirements. Options: (1) 2- way louvered exhaust grill;
(2) exterior primer coating. How to Order: state model, housing
size, motor specifications, blower specifications |
|
FILTER-MATE® Motor-blower Assembly Specifications
Industrial Models |
MODEL |
DIMENSION
H x W x D
(inches) |
SHPG.
WT.
(lbs) |
SER-
VICE
CLR.
(in) |
MOTOR |
BLOWER
WHEEL
Diameter
backward inclined |
C.F.M. at external
static pressure.
R.P.M.* |
MH-33 - 1 x 1 - BI |
28.0 x 24 x 33.75 |
|
|
3 H.P., 208-230/460 V.A.C., 3450 rpm, F.L.A. 8.3-7.6/3.8, 60 Hz.,
3 Phase |
12; BI SWSI CLI |
2000 cfm up to 3.5" TSP, 2921 rpm, BHP 1.95 |
MH-42
- 1 x 2 - BI |
28.0
x 48 x 42 |
500 |
69 |
5
H.P., 208-230/460 V.A.C., 3450 rpm, F.L.A. 14.0-13.0/6.5, 60 Hz. 3
Phase |
12"
BI DWDI CLI |
4000
cfm up to 3.5" TSP, 2948 rpm, BHP 3.63 |
MH-50 - 2 x 2 - BI |
51.5 x 48 x 50 |
|
|
10 H.P., 208-230/460 V.A.C., 1725 rpm, F.L.A. 27.2-24.6/12.30 |
16" BI DWDI CLI |
8000 cfm up to 3.5" TSP, 2289 rpm, BHP 7.6 |
MH-57
- 2 x 3 - BI |
51.5
x 72 x 57 |
850 |
72 |
15
H.P., 208-230/460 V.A.C., 1725 rpm, F.L.A. 40.5-38.0/19.0 |
20"
BI DWDI CLI |
12000
cfm up to 3.5" TSP, 1897 rpm, BHP 12.1 |
MH-65 - 3 x 3 - BI |
75.75 x 72 x 65 |
|
|
20 H.P., 208-230/460 V.A.C., 1725 rpm, F.L.A. 54-49/24.50 |
24" BI DWDI CLI |
18000 cfm up to 3.5" TSP, 1528 rpm, BHP 17.1 |
*Larger Models availible up to 50,000 cfm on a custom order basis.
Backward inclined and airfoil fans availble for higher static pressure
requirements. Options: (1) 2- way louvered exhaust grill; (2)
exterior primer coating. How to Order: state model, housing