BULLETIN NO. 1400

AIR CLEANING SYSTEMS AND
EQUPMENT BY
R. M.E. I., INC.

The Competitive Edge - Filter-Mate Has it all. Here's Why...
  • Eliminates "in the room" air cleaners which are unsightly, expensive, noisy, and take up valuable space. Our units work above the ceiling in either the existing CH&A ductwork systems, or an easily installed independent flex duct system.
  • Modular filter housings and motor-blower housings are separate. They can easily be connected to form one unit or placed in separate locations connected by a duct line.
  • Modular motor-blower housing assemblies offset the additional pressure drop created by the filter bank and maintains the original balanced flow of the HVAC system.
  • Side loaded filter housings accept up to five stages of progressive density filtration for efficient filter application. Filter choices include: panel prefilters, mist collectors, spark arrestors, extended surface pleats, V-bags, HEPAS, partial bypass or solid bed panels containing up to 90 pounds of activated charcoal or activated alumina. Multiple height-width filter housings are available.
  • The ability for you to select a "filter-motor-blower" combination provides for unlimited versatility.
  • Motor-blower housings accept motors of any frame and size and blowers from 100 to 50,000 cfm.
  • Our Technical and engineering support helps you select the correct filter-motor-blower combinations for your particular application.
Filter-Mate... Built to Last
  • Modular
  • Compact
  • U.L. Listed Electrical Componets
  • Rugged Construction
  • Fully Sealed
  • Easy Installation
  • Quiet Operation
  • Easy To Service
  • Non Electrostatic
  • Energy Efficient
  • Side Access
  • Removes Particulates
  • Remove Odors


APPLICATIONS

RESIDENTIAL:    Remove Dust, pollen, mold spores, cooking odors, cigarette smoke, formaldehyde.
COMMERCIAL:    Remove heavy cigarette smoke and odors, food odors, restroom odors, paper dust, toner dust.
INDUSTRIAL:    Remove welding fumes, airborn dusts, airborn lint and fibers, odors, vapors, gasses, oil mists, smoke, cotton dusts, asbestos
HOW TO SPECIFY DESIGN & CONSTRUCTION
The MH-series shall be a side access air handling system consisting of a housing with positively sealed, hinged access door(s), Motor and belt drive at blower. Cabinet is made of 16 gage galvanized steel with 1-1/2 standing flanges and 2 channel corner posts designed to interface with FH-series filter housings and ductwork. Electrical wiring is terminated at an externally mounted junction box. Drive section consists of adjustable pitch sheave, solid cast iron sheave and heavy duty V-belt. Motor mount is adjustable for controlling belt tension. motor, blower size, and electrical requirements vary according to model.

The FH-series shall be a side access with multi-stage filter system consisting of a housing, access door(s), tracks and universal holding frames. Housing shall accept filter combinations listed under specifications. The cabinet consists of 16 gage galvanized steel with 1-1/2 standing flanges and 2 channel corner posts designed to interface with MH-series Motor-blower housings and ductwork. Access doors are 16 gage galvanized steel with replaceable positive sealing latches and replaceable hinges. Access doors and filter compartment is gasketed for air tight seal. Flanges are notched for water runoff and cabinets are suitable for out door installation.


APPLICATION

The MH-series air handlers are used to push or draw air through FH-series filter housings. The aire handler system and filter housing can be used separately or together with or without ductwork to provide a high efficiency air cleaning system capable of accepting a wide variety of high efficiency media filtration. Filter media types would include prefilters, pleated cartriges, V-bags, HEPAS, activated charcoal and activated alumina, mist collectors and spark arrestors. In a commercial application this system is designed to operate as an independently concealed system above the ceiling. It can either operate separate and indepent of the central heat and air system or in conjunction with an existing system. In an industrial application this system can also be used in a free hanging position for general air cirulation. It can be attached to one or more pick up hoses for direct source capture or aattached to a canopy hood for general source in welding, grinding, cutting and boring operations.
FILTER-MATE® Filter Housing Assembly Specifications
Model
DIMENSION
H x W x D
(inches)
SHPG.
WT.
(lbs)
C.F.M at
500 F.P.M.
face
velocity
SER-
VICE
CLR.
(in)
FILTER
Stages*
(max.)
Quantity &
Filter Face
Dimension**
(inches)
Filter Combinations
Availble
FH-14 - 1/2 x 1
FH-14 - 1 x 1
FH-14 - 1 x 2
FH-14 - 1 x 3
FH-14 - 2 x 2
FH-14 - 2 x 3
FH-14 - 3 x 3
27.25 x 24 x 14
27.25 x 48 x 14
27.25 x 72 x 14
51.50 x 48 x 14
51.50 x 72 x 14
75.75 x 72 x 14
43
65
80
100
131
175
1000
2000
3000
4000
6000
9000
26"
26"
26"
26"
26"
26"
two
two
two
two
two
two
1 - 24 x 24
2 - 24 x 24
3 - 24 x 24
4 - 24 x 24
6 - 24 x 24
9 - 24 x 24
ASHRAE or
charcoal
FH-21 - 1/2 x 1
FH-21 - 1 x 1
FH-21 - 1 x 2
FH-21 - 1 x 3
FH-21 - 2 x 2
FH-21 - 2 x 3
FH-21 - 3 x 3
15.25 x 24 x 21
27.25 x 24 x 21
27.25 x 48 x 21
27.25 x 72 x 21
51.50 x 48 x 21
51.50 x 72 x 21
75.75 x 72 x 21
92
120
173
232
254
332
430
1000
2000
4000
6000
8000
12000
18000
26"
26"
26"
26"
26"
26"
26"
two
two
two
two
two
two
two
1 - 12 x 24
1 - 24 x 24
2 - 24 x 24
3 - 24 x 24
4 - 24 x 24
6 - 24 x 24
9 - 24 x 24
2" prefilter + 12" pleated
ASHRAE or charcoal
FH-27 - 1 x 1
FH-27 - 1 x 2
FH-27 - 1 x 3
FH-27 - 2 x 2
FH-27 - 2 x 3
FH-27 - 3 x 3
28.5 x 26.38 x 27
28.5 x 52.00 x 27
28.5 x 76.50 x 27
52.5 x 52.00 x 27
52.5 x 77.63 x 27
76.5 x 77.63 x 27
170
242
311
340
418
519
2000
4000
6000
8000
12000
18000
26"
26"
26"
26"
26"
26"
two
two
two
two
two
two
1 - 24 x 24
2 - 24 x 24
3 - 24 x 24
4 - 24 x 24
6 - 24 x 24
9 - 24 x 24
99.97 D.O.P. standard
or high capacity
FH-33 - 1/2 x 1
FH-33 - 1 x 1
FH-33 - 1 x 2
FH-33 - 1 x 3
FH-33 - 2 x 2
FH-33 - 2 x 3
FH-33 - 3 x 3
15.25 x 24 x 33.75
27.25 x 24 x 33.75
27.25 x 48 x 33.75
27.25 x 72 x 33.75
51.50 x 48 x 33.75
51.50 x 72 x 33.75
75.75 x 72 x 33.75
120
155
224
300
328
429
556
1000
2000
4000
6000
8000
12000
18000
33"
33"
33"
33"
33"
33"
33"
three
three
three
three
three
three
three
1 - 12 x 24
1 - 24 x 24
2 - 24 x 24
3 - 24 x 24
4 - 24 x 24
6 - 24 x 24
9 - 24 x 24
2" or 4" prefilter + 12"
pleated ASHRAE
+ 8" solid bed charcoal OR
4" oil coelescer
or spark arrestor +
2" prefilter +
12" pleated ASHRAE OR
4" oil coelescer
or spark arrestor +
2" prefilter + 24" V-bag
FH-42 - 1 x 1
FH-42 - 1 x 2
FH-42 - 1 x 3
FH-42 - 2 x 2
FH-42 - 2 x 3
FH-42 - 3 x 3
27.25 x 24 x 42
27.25 x 48 x 42
27.25 x 72 x 42
51.50 x 48 x 42
51.50 x 72 x 42
75.75 x 72 x 42
235
340
456
500
653
845
2000
4000
6000
8000
12000
18000
36"
36"
36"
36"
36"
36"
four
four
four
four
four
four
1 - 24 x 24
2 - 24 x 24
3 - 24 x 24
4 - 24 x 24
6 - 24 x 24
9 - 24 x 24
OR 2" prefilter + 36" V-bag
FH-33-CF - 1/2 x 1
FH-33-CF - 1 x 1
FH-33-CF - 1 x 2
FH-33-CF - 1 x 3
FH-33-CF - 2 x 2
FH-33-CF - 2 x 3
FH-33-CF - 3 x 3
15.25 x 24 x 33.75
27.25 x 24 x 33.75
27.25 x 48 x 33.75
27.25 x 72 x 33.75
51.50 x 48 x 33.75
51.50 x 72 x 33.75
75.75 x 72 x 33.75
200
330
527
800
920
1202
1550
1000
2000
4000
6000
8000
12000
18000
33"
33"
33"
33"
33"
33"
33"
two
two
two
two
two
two
two
1 - 12 x 24
1 - 24 x 24
2 - 24 x 24
3 - 24 x 24
4 - 24 x 24
6 - 24 x 24
9 - 24 x 24
2" prefilter + 90 lbs.
of virgin activated
charcoal in 10 refillable
trays per 24" x 24"
face area

-- Activated
Alumina
Optional --

** Accepts holding frame or headered primary
HOW TO ORDER: State model, housing size, filter size, type, efficiency, and quantity.
Design and Specifications subject to change without notice.


SUGGESTED HOUSING ARRANGEMENTS

APPLICATION AIRFLOW
HOSPITAL    Prefilter 95% ASHRAE Motor/Blower 99% HEPA
COMMERCIAL    Prefilter 95% ASHRAE or 95% HEPA Motor/Blower Charcoal 40% ASHRAE
INDUSTRIAL    Prefilter 55-95% ASHRAE 95% HEPA Charcoal Motor/Blower
OIL MIST    Mist Collector Prefilter 95% ASHRAE Motor/Blower

* Certain Stages may be deleted or added depending on the specific application.
# Diffuser location if Motor housing interfaces directly with downstream filter.


FILTER-MATE® Motor-blower Assembly Specifications
Commercial Models
MODEL
DIMENSION
H x W x D
(inches)
SHPG.
WT.
(lbs)
SER-
VICE
CLR.
(in)
MOTOR
BLOWER
WHEEL
Diam. x Width (in)
forward inclined
C.F.M. at external
static pressure.
R.P.M.*
  MH-21 - 1/2 x 1
15.50 x 24 x 21
 
 
 
 
1/3 H.P., 115 V.A.C., F.L.A. 6.0, 1725 rpm 60 Hz.
7 x 5
600 cfm @ 1.3" TSP, 1800 rpm, BHP .27
MH-23 - 1/2 x 1
15.50 x 24 x 23
93
49
1/3 H.P., 115 V.A.C., F.L.A. 6.0, 1725 rpm 60 Hz.
9 x 7
800 cfm @ 0.70" TSP, 850 rpm, BHP .16
MH-33 - 1/2 x 1
15.50 x 24 x 23
 
 
1/2 H.P., 115 V.A.C., F.L.A. 8.0, 1725 rpm 60 Hz.
9 x 7
1000 cfm @ 1.5" TSP, 1257 rpm, BHP .43
MH-23 - 1 x 1
27.25 x 24 x 23
127
55
3/4 H.P., 115/230 V.A.C., F.L.A. 11.4/5.7, 1725 rpm 60 Hz.
10 x 10
2000 cfm @ 1.0" TSP, 950 rpm, BHP .70
MH-33 - 1 x 1
27.25 x 24 x 33.75
 
 
 
 
2.0 H.P., 230/460 V.A.C., F.L.A. 6.0/3.0, 1725 rpm 60 Hz. 3 Phase
12 x 12
2500 cfm @ 1.8" TSP, 1106 rpm, BHP 1.23
MH-42 - 1 x 2
27.25 x 48 x 42
300
67
3.0 H.P., 230/460 V.A.C., F.L.A. 8.4/4.2, 1725 rpm 60 Hz. 3 Phase
15 x 15
5000 cfm @ 1.80" TSP, 912 rpm, BHP 2.90
MH-42 - 1 x 3
27.25 x 48 x 42
 
 
5.0 H.P., 230/460 V.A.C., F.L.A. 13.0/6.5, 1725 rpm 60 Hz. 3 Phase
15 x 15
6000 cfm @ 1.80" TSP, 933 rpm, BHP 4.05
MH-50 - 2 x 2
51.50 x 48 x 50
450
55
5.0 H.P., 230/460 V.A.C., F.L.A. 13.0/6.5, 1725 rpm 60 Hz. 3 Phase
18 x 18
8000 cfm @ 1.80" TSP, 750 rpm, BHP 4.35
MH-57 - 2 x 3
51.50 x 72 x 57
 
 
10 H.P., 230/460 V.A.C., F.L.A. 24.6/12.3, 1725 rpm 60 Hz. 3 Phase
20 x 20
12000 cfm @ 2.0" TSP, 755 rpm, BHP 7.90
MH-57 - 3 x 3
75.75 x 72 x 57
750
68
15 H.P., 230/460 V.A.C., F.L.A. 38.0/19.0, 1725 rpm 60 Hz. 3 Phase
22 x 22
18000 cfm @ 2.0" TSP, 754 rpm, BHP 14.30
*Larger Models availible up to 50,000 cfm on a custom order basis. Backward inclined and airfoil fans availble for higher static pressure requirements. Options: (1) 2- way louvered exhaust grill; (2) exterior primer coating. How to Order: state model, housing size, motor specifications, blower specifications

FILTER-MATE® Motor-blower Assembly Specifications
Industrial Models
MODEL DIMENSION
H x W x D
(inches)
SHPG.
WT.
(lbs)
SER-
VICE
CLR.
(in)
MOTOR BLOWER
WHEEL
Diameter
backward inclined
C.F.M. at external
static pressure.
R.P.M.*
MH-33 - 1 x 1 - BI 28.0 x 24 x 33.75     3 H.P., 208-230/460 V.A.C., 3450 rpm, F.L.A. 8.3-7.6/3.8, 60 Hz., 3 Phase   12; BI SWSI CLI 2000 cfm up to 3.5" TSP, 2921 rpm, BHP 1.95
MH-42 - 1 x 2 - BI 28.0 x 48 x 42 500 69 5 H.P., 208-230/460 V.A.C., 3450 rpm, F.L.A. 14.0-13.0/6.5, 60 Hz. 3 Phase 12" BI DWDI CLI 4000 cfm up to 3.5" TSP, 2948 rpm, BHP 3.63
MH-50 - 2 x 2 - BI   51.5 x 48 x 50     10 H.P., 208-230/460 V.A.C., 1725 rpm, F.L.A. 27.2-24.6/12.30 16" BI DWDI CLI 8000 cfm up to 3.5" TSP, 2289 rpm, BHP 7.6
MH-57 - 2 x 3 - BI 51.5 x 72 x 57 850 72 15 H.P., 208-230/460 V.A.C., 1725 rpm, F.L.A. 40.5-38.0/19.0 20" BI DWDI CLI 12000 cfm up to 3.5" TSP, 1897 rpm, BHP 12.1
MH-65 - 3 x 3 - BI 75.75 x 72 x 65     20 H.P., 208-230/460 V.A.C., 1725 rpm, F.L.A. 54-49/24.50 24" BI DWDI CLI 18000 cfm up to 3.5" TSP, 1528 rpm, BHP 17.1
*Larger Models availible up to 50,000 cfm on a custom order basis. Backward inclined and airfoil fans availble for higher static pressure requirements. Options: (1) 2- way louvered exhaust grill; (2) exterior primer coating. How to Order: state model, housing size, motor specifications, blower specifications